Built-in Bypass Soft-Starter

Product Overview This series of soft starters adopts a three-input and three-outlet structure design, and the complete set of cabinets does not need an external AC contactor; the interior uses a three-phase independent bypass contactor DC coil design to ensure that it is not affected by voltage drop and thus ensures reliable operation of the equipment! Small and classic, with perfect motor comprehensive protection function! This product is widely used in the starting control of transmission equipment, fans, pumps, crushers and other loads....

January 4, 2024 · 5 min · 870 words · Gaylen

Three-phase vector inverter

Product Overview The vector frequency converter is a power control device that uses frequency conversion technology and microelectronics technology to control the AC motor by changing the frequency of the motor’s operating power supply. The frequency converter is mainly composed of rectification, filtering, inverter, braking unit, drive unit, detection unit, micro processing unit etc. The frequency converter adjusts the voltage and frequency of the output power supply by switching off the internal GBT, and provides the required power supply voltage according to the actual needs of the motor, thereby achieving the purpose of energy saving and adjustment....

January 4, 2024 · 3 min · 529 words · Gaylen

External Bypass Soft-Starter

Product Overview This series of soft starters is an external bypass type, with a structure design of six inputs and three outputs. It is small and exquisite, and has a complete motor comprehensive protection function. The complete set of cabinets does not need an external protector, but it must be used with an external AC contactor. , After the soft starter is started, the AC contactor runs at full pressure, the product is more stable and reliable, and has a long service life....

January 2, 2024 · 5 min · 888 words · Gaylen

On-line soft starter

Product Overview This series of soft starters adopts three-in, three-out thyristor full-time online structure, and does not need external AC contactors to form a set cabinet; High-power air-cooled radiator and high-speed axial fan are used inside to ensure long-term reliable operation of soft start; When using, be sure to consider the exhaust air in the cabinet to dissipate heat! This product is widely used in the starting control of transmission equipment, fans, pumps, crushers and other loads, and the product complies with GB14048....

January 2, 2024 · 5 min · 865 words · Gaylen